PP Functioning of seepage system

PP Functioning of seepage system
Context PP Ontpoldering Perkpolder
Decompositie type IOR

Activity



Figure 1: Cross-section (left) and map (right) showing the position of the seepage system and the new tidal area. The thickness of the fresh water lens (left) was determined in monitoring points EC102, EC101 and EC111 using EM-SlimFlex (Boersema et al. 2016).

Below the adjacent agricultural area, a freshwater lens of about 10 to 15 meters provides farmers with fresh groundwater for irrigating their crops (figure 1). In order to protect this freshwater lens from shrinking, a self-flowing seepage system, called SeepCat, was designed and installed to compensate the effects resulting from this local sea level rise.

The freshwater lens below the agricultural area is one of the Badon Ghyben Herzberg type and will eventually shrink when hydraulic heads below the lens increase caused by the local sea level rise. The task of SeepCat is to release the increased pressure in the aquifer preventing the freshwater lens to decrease in size. The self-flowing seepage system consists of 61 vertical seepage wells with 5-10 m long screens, installed in the aquifer at 12 to 17 m depth. The distance between the wells is 15 to 20 m and the total length of the seepage system is 1100 m. The vertical seepage wells are connected in the subsoil with horizontal tubes which end up in control units (figure 2). The hydraulic head gradient (Δh) can be regulated by raising or lowering the water level in the control unit using weirs (figure 2). In this way the discharge of the seepage system can be regulated. Since the hydraulic head in the aquifer is higher than the surface water level in the control unit and ditch, seepage wells are artesian and self-flowing and no pumps are needed to extract the groundwater from the aquifer. The extracted seepage water is discharged into the surface water system and transported to a pumping station (at 1 km) where it is pumped out of the polder into the sea.

Figure 2: Cross section of self-flowing seepage system with seepage pipes and control unit (left) and photo of control unit with weir (right) (Boersema et al. 2016).




De View-Navigation (VN) pagina's.


De links naar andere pagina's.

Produceert
Consumeeert
Onderdeel van PP Groundwater processes
Instantie van
Betreft


Draagt bij aan.

Draagt bij aan PP Saline groundwater in adjacent area
Waarde --
Opmerkingen


De pagina's die linken naar deze pagina.

Dit element heeft geen subelementen.

Komt van Type Connectie type Conditie Waarde Opmerkingen
PP Saline groundwater in adjacent area Refers this page, figure 1
PP Seepage of saline water Connects seq
HZ University of Applied Sciences
Rijkswaterstaat, Ministerie van Infrastructuur en Milieu
Projectbureau Zeeweringen
Waterschap Scheldestromen
Provincie Zeeland
Deltares